Passa alla casella di ricercaPassa alla navigazionePassa al contenuto principale

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

  • The ATLAS collaboration
  • A. Alikhanian Yerevan Institute of Physics
    ,
  • Abdus Salam International Centre for Theoretical Physics
    ,
  • Academia Sinica - Institute of Physics
    ,
  • AGH University of Krakow
    ,
  • Aix-Marseille Université
    ,
  • Alexandru Ioan Cuza University of Iaşi
Prodotto della ricerca:
Contribution to journal
Article
Peer review

Open Access

Publication Information

Tipo di output

Prodotto della ricerca:
Contribution to journal
Article
Peer review

Lingua originale

English

Numero dell’articolo

P05063

Rivista (volume, numero edizione)

Journal of Instrumentation (Volume 19, Edizione 5)

Attività cardine della pubblicazione

  • Published - 01/05/2024

Stato pubblicazione

Published - 01/05/2024

Publication IDs

  • Scopus: 85196183700

Abstract

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 1034 cm-2 s-1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 1034 cm-2 s-1, with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.